    A flammability test for dielectric fluids

  • Author

    L. Mandelcorn;R. L. Miller

  • Author_Institution
    Westinghouse Research Laboratories, Pittsburgh, Pennsylvania 15235, USA
  • fYear
    1976
  • fDate
    6/1/1976 12:00:00 AM
  • Firstpage
    170
  • Lastpage
    172
  • Abstract
    A modification or the Cleveland Open Cup Test, ASTM D92, was developed for dielectric fluids in non-fire hazard power capacitors and transformers. This was on the basis of considering fire situations in these apparatus. Two criteria for non-flammability were deduced and applied in this test: that burning may only be initiated at the boiling point, and that burning cease on cooling when separated from the heat source. A number of fluids were tested. Effects of soot are noted.
  • Keywords
    "Electric breakdown","Temperature measurement","Films","Temperature dependence","Breakdown voltage","Epoxy resins","Electric fields"