The influence of a dc bias on streamers produced by step voltages in transformer oil with and without insulating surfaces
Author :
S. J. Rzad;J. C. Devins;R. J. Schwabe
Author_Institution :
General Electric Company, Corporate Research and Development, P.O. Box 8, Schenectady, New York 12301, United States
fYear :
1982
fDate :
6/1/1982 12:00:00 AM
Firstpage :
259
Lastpage :
259
Abstract :
Using shadowgraphic techniques in conjunction with an Imacon camera, measurements of streamer velocities and minimum voltage required for streamer propagation (MVP) have been made with and without dc superimposed on voltage steps (1.2 ?s rise time). This has been done in point-plane geometries and semi-uniform fields in a transformer oil alone as well as with pressboard barriers. Velocities and MVP have also been measured for streamers propagating on the surface between cylindrical electrodes perpendicular to insulating sheets having a ground plane on the opposite side. Again the influence of superimposed dc was assessed. The solid materials used were polymethylmethacrylate and pressboard. Measurements with the latter material were made using an optical multichannel analyzer to follow the light emission from the propagating streamer.
Keywords :
"Voltage measurement","Power transformer insulation","Oil insulation","Velocity measurement","Optical variables measurement","Companies","Research and development"