Effects of fluid flow on the electric field distribution in charged liquid dielectrics
Author :
Markus Zahn;Masheed Saidi
Author_Institution :
Massachusetts Institute of Technology, High Voltage Research Laboratory, Building N-10, Cambridge, 02139, United States
fYear :
1982
fDate :
6/1/1982 12:00:00 AM
Firstpage :
281
Lastpage :
282
Abstract :
A one dimensional drift dominated conduction model is used with a flowing charged dielectric to describe the transient and dc steady state electric field and space charge distributions. This work extends past similar work1 but now allows for forced convection of the liquid dielectric in the same or opposite direction of the electric field resulting in convection currents as well as conduction and displacement currents. The resulting governing partial differential equations are of the hyperbolic type and are solved using the method of characteristics. Particular case studies examine the steady state distributions.
Keywords :
"Electric fields","Electrodes","Dielectrics","Steady-state","Space charge","Fluid flow","Transient analysis"