Dynamometer test of induction motors rewound using Wanlass redesign techniques
Author :
Charles A. Koffler
Author_Institution :
President &
fYear :
1983
Firstpage :
336
Lastpage :
338
Abstract :
Tests of squirrel cage induction motors rewound to the so-called Wanlass redesign were made using dynamometers to evaluate energy savings over conventionally wound motors. Results of these tests are outlined. It was concluded that final motor efficiencies are not predictable and that a reduction in efficiency sometimes resulted.
Keywords :
"Testing","Induction motors","Windings","Capacitors","Maintenance engineering","Electric motors","Stator windings"