DocumentCode
3772658
Title
Analysis of moisture in oil-impregnated paper tapes
Author
Madelyn A. Roto;Julian F. Johnson;Dwight H. Damon;John S. Engelhardt
Author_Institution
Electrical Insulation Research Center, Institute of Materials Science, University of Connecticut Storrs, Connecticut 06268
fYear
1983
Firstpage
354
Lastpage
358
Abstract
The Dupont Moisture Analyzer, model #903, has been successfully used in our laboratories to measure moisture content in the ppm range in oil impregnated paper tape samples. The Dupont 903 utilizes a coulometric technique to quantitatively determine moisture levels. Present work indicates that the best results are obtained by heating at 70°C, higher temperatures cause decomposition of the paper. Reproducible results are only obtained with careful sample preparation and handling.
Keywords
"Moisture","Heating","Splicing","Cable insulation","Standards","Coatings"