DocumentCode :
3772767
Title :
Study of the open loop and closed loop oscillator techniques
Author :
George R. Imel;Benjamin Baker;Tony Riley;Adam Langbehn;Harishchandra Aryal;M. Lamine Benzerga
Author_Institution :
Nuclear Engineering at Idaho State University, Pocatello, Idaho
fYear :
2015
fDate :
4/1/2015 12:00:00 AM
Firstpage :
1
Lastpage :
8
Abstract :
This paper presents some aspects of a five year study undertaken at Idaho State University of the measurement of very small worth reactivity samples comparing open and closed loop oscillator techniques. The study conclusively demonstrated the equivalency of the two techniques with regard to uncertainties in reactivity values, i.e., limited by reactor noise. As those results are thoroughly documented in recent publications, in this paper we will concentrate on the support work that was necessary. For example, we describe in some detail the construction and calibration of a pilot rod for the closed loop system. We discuss the campaign to measure the required reactor parameters necessary for inverse-kinetics. Finally, we briefly discuss the transfer of the open loop technique to other reactor systems.
Keywords :
"Inductors","Oscillators","Actuators","Uncertainty","Kinetic theory","Data acquisition","Neutrons"