Title :
SiC-based neutron detector in quasi-realistic working conditions: Efficiency and stability at room and high temperature under fast neutron irradiations
Author :
Raffaello Ferone;Fatima Issa;Dora Szalkai;Axel Klix;Laurent Ottaviani;Stephane Biondo;Vanessa Vervisch;Ludo Vermeeren;Richard Saenger;Abadallah Lyoussi
Author_Institution :
IM2NP (UMR CNRS 7334), Aix-Marseille University, Case 231, 13397 Marseille Cedex 20, France
fDate :
4/1/2015 12:00:00 AM
Abstract :
In the framework of the European I_SMART project, we have designed and made new SiC-based nuclear radiation detectors able to operate in harsh environments and to detect both fast and thermal neutrons. In this paper, we report experimental results of fast neutron irradiation campaign at high temperature (106 °C) in quasi-realistic working conditions. Our device does not suffer from high temperature, and spectra do show strong stability, preserving features. These experiments, as well as others in progress, show the I_SMART SiC-based device skills to operate in harsh environments, whereas other materials would strongly suffer from degradation. Work is still demanded to test our device at higher temperatures and to enhance efficiency in order to make our device fully exploitable from an industrial point of view.
Keywords :
"Neutrons","Thermal stability","Silicon carbide","Temperature measurement","Radiation effects","Detectors","Temperature sensors"
Conference_Titel :
Advancements in Nuclear Instrumentation Measurement Methods and their Applications (ANIMMA), 2015 4th International Conference on
DOI :
10.1109/ANIMMA.2015.7465545