• DocumentCode
    3772787
  • Title

    Calculation to experiment comparison of SPND signals in various nuclear reactor environments

  • Author

    Lo?c Barbot;Vladimir Radulovic;Damien Fourmentel;Luka Snoj;Mikolaj Tarchalski;V?ronique Dewynter-Marty;Fadhel Malouch

  • Author_Institution
    CEA, DEN, DER, Instrumentation, Sensors and Dosimetry Laboratory, Cadarache, F-13108 St-Paul-Lez-Durance, France
  • fYear
    2015
  • fDate
    4/1/2015 12:00:00 AM
  • Firstpage
    1
  • Lastpage
    7
  • Abstract
    In the perspective of irradiation experiments in the future Jules Horowitz Reactor (JHR), the Instrumentation Sensors and Dosimetry Laboratory of CEA Cadarache (France) is developing a numerical tool for SPND design, simulation and operation. In the frame of the SPND numerical tool qualification, dedicated experiments have been performed both in the Slovenian TRIGA Mark II reactor (JSI) and very recently in the French CEA Saclay OSIRIS reactor, as well as a test of two detectors in the core of the Polish MARIA reactor (NCBJ). A full description of experimental set-ups and neutron-gamma calculations schemes are provided in the first part of the paper. Calculation to experiment comparison of the various SPNDs in the different reactors is thoroughly described and discussed in the second part. Presented comparisons show promising final results.
  • Keywords
    "Inductors","Neutrons","Detectors","Radiation effects","Monte Carlo methods","Monitoring","Instruments"
  • Publisher
    ieee
  • Conference_Titel
    Advancements in Nuclear Instrumentation Measurement Methods and their Applications (ANIMMA), 2015 4th International Conference on
  • Type

    conf

  • DOI
    10.1109/ANIMMA.2015.7465558
  • Filename
    7465558