Title :
Performance of an RPM based on Gd-lined plastic scintillator for neutron and gamma detection
Author_Institution :
Istituto Nazionale di Fisica Nucleare (INFN), Via Dodecaneso N.33, 16146 Genova, Italy
fDate :
4/1/2015 12:00:00 AM
Abstract :
INFN and ANN designed and developed a Radiation Portal Monitor (RPM) to detect gamma and neutron radiations using plastic scintillator coupled to Gadolinium. The system is a portal for the screening of vehicle and cargo containers aiming at detecting the presence of radioactive elements and, in particular, Special Nuclear Materials (SNM). The system was calibrated based on static measurements at the INFN laboratory and characterized with dynamic tests at the the JRC ITRAP+10 facility. Results showed that the system is not only compliant to international standards of its category, but exceeds them in most of the cases, demonstrating the validity of the novel technology and of the implemented layout.
Keywords :
"Detectors","Neutrons","Benchmark testing","Prototypes","Plastics","Portals"
Conference_Titel :
Advancements in Nuclear Instrumentation Measurement Methods and their Applications (ANIMMA), 2015 4th International Conference on
DOI :
10.1109/ANIMMA.2015.7465640