DocumentCode
3773211
Title
New considerations in flammability testing of lead and hook-up wires
Author
R. L. Spade
Author_Institution
Beiden Corporation, Geneva, Illinois
fYear
1973
Firstpage
48
Lastpage
51
Abstract
Flammability resistance in all types of products is a desirable characteristic so long as it permits the product to fulfill its expected function. Wire and cable manufacturers have felt a special responsibility since their products are subject to temperature rises from the current they carry, they are often located in paths winding through a structure or apparatus and are often the nerve system for controls and safety circuits which must be kept operating.
Keywords
"Fires","Temperature measurement","Wires","TV","Receivers","Temperature","Plastics"