• DocumentCode
    3773226
  • Title

    Reliability testing of aluminum magnet wire connections for hermetic motors

  • Author

    Jerry L. Spears

  • Author_Institution
    Electric Motor Division, A.O. Smith Corporation, Tipp City, Ohio
  • fYear
    1973
  • Firstpage
    95
  • Lastpage
    98
  • Abstract
    Economic considerations not withstanding, aluminum magnet wire for hermetic motors offers other advantages. For example, there is evidence of better resistance to long-term aging when organic insulations are applied to aluminum wire. It is common experience that aluminum wire winds easier once proper tensions are adjusted. Springback characteristics which are inherently less in aluminum wire allow for better coil conformation and more efficient use of available space. These advantages partially offset the lower conductivity values of aluminum wire. Historically, however, the primary drawback in using aluminum magnet wire has been in the development of a process to insure that reliable connections could be made.
  • Keywords
    "Wires","Aluminum","Stator windings","Magnetomechanical effects","Testing","Insulation"
  • Publisher
    ieee
  • Conference_Titel
    Electrical Insulation Conference, 1973 EIC 11th
  • Print_ISBN
    978-1-5090-3110-8
  • Type

    conf

  • DOI
    10.1109/EIC.1973.7468653
  • Filename
    7468653