Security and speed assessment of a new distance protection algorithm based on the wavelet transform
Author
Sini?a Zubi?;Przemys?aw Balcerek
Author_Institution
ABB Corporate Research Center, Krakow, Poland
fYear
2015
fDate
7/1/2015 12:00:00 AM
Firstpage
1
Lastpage
5
Abstract
Distance relay algorithms are typically based on the phasor-domain approach where the fundamental frequency phasors are computed using well-known methods such as: the full cycle discrete Fourier transformation (FCDFT), least error squares (LES) and the discrete wavelet transform (DWT). Instead of the phasor-domain approach, there are time-domain based algorithms that detect faults without calculating the phasors. In this paper a new distance relay algorithm based on the time-domain approach and DWT is introduced. The security of fault detection and the tripping time obtained when applying the proposed algorithm to a number of fault simulations is compared with the equivalent results obtained when applying the classical solution based on DFT.
Keywords
"Security","Discrete wavelet transforms","Discrete Fourier transforms","Finite impulse response filters","Protective relaying","Time-domain analysis","Power harmonic filters"