• DocumentCode
    377493
  • Title

    The effect of noise on transverse emittance growth in the Tevatron

  • Author

    Tan, C.Y. ; Steimel, J.M.

  • Author_Institution
    Fermi Nat. Accel. Lab., Batavia, IL, USA
  • Volume
    3
  • fYear
    2001
  • fDate
    2001
  • Firstpage
    1874
  • Abstract
    Emittance growth due to noise from a transverse beam feedback system are discussed. A theory for calculating emittance growth rate as a function of the feedback system´s measured open loop transfer function is derived. A simple feedback system was installed, measured, and tested in the Fermilab Tevatron, and the emittance growth rate results agree very closely with the theory
  • Keywords
    beam handling equipment; colliding beam accelerators; noise; particle beam stability; proton accelerators; synchrotrons; Tevatron; emittance growth rate; noise effect; open loop transfer function; transverse beam feedback system; transverse emittance growth; Density measurement; Feedback loop; Life estimation; Particle accelerators; Particle beam measurements; Particle beams; Particle measurements; Storage rings; System testing; Transfer functions;