• DocumentCode
    3775767
  • Title

    Review of ECG signal de-noising techniques

  • Author

    Youssef Aiboud;Jamal El Mhamdi;Abdelilah Jilbab;Hamza Sbaa

  • Author_Institution
    Electrical Engineering Research Laboratory (LRGE) Mohammed V University, ENSET Rabat, Morocco
  • fYear
    2015
  • Firstpage
    1
  • Lastpage
    6
  • Abstract
    The aim of this study is to compare different algorithms destined to de-noise an ECG signal, starting with a normal FIR filter to eliminate the noise. Three other filtering methods are used: a Kalman filter and an LMS filter alongside with the undecimated wavelet transform. These three are considered as adaptive filters that essentially minimize the mean-squared error between the noisy ECG and a reference input, which is either noise that is correlated with the noise in the primary input or a signal that is correlated only with ECG in the primary input. To have a better view of the results, two random ECG signals from the Physiobank database are used.
  • Keywords
    "Electrocardiography","Adaptive filters","Finite impulse response filters","Kalman filters","Transforms","Filtering algorithms"
  • Publisher
    ieee
  • Conference_Titel
    Complex Systems (WCCS), 2015 Third World Conference on
  • Type

    conf

  • DOI
    10.1109/ICoCS.2015.7483313
  • Filename
    7483313