DocumentCode :
3775803
Title :
The Leap Motion movement for 2D pointing tasks: Characterisation and comparison to other devices
Author :
Manuel C?sar Bessa Seixas;Jorge C. S. Cardoso;Maria Teresa Galv?o Dias
Author_Institution :
CITAR/School of Arts, Portuguese Catholic University, Porto, Portugal
fYear :
2015
Firstpage :
15
Lastpage :
24
Abstract :
In this paper we present the results from an experiment designed to characterize the Leap Motion movement in 2D pointing tasks and compare it to a mouse and touchpad. We used the ISO 9241-9 multi-directional tapping test for comparing the devices, and we analyse the results using standard throughput and error rate measures as well as additional accuracy measures such as target re-entry, task axis crossing, movement direction change, orthogonal direction change, movement variability, movement offset, and movement error. We also present the results from the ISO 9241-9 assessment of comfort questionnaire, and our observations from the participant´s postures when using the Leap Motion device. Results indicate that the Leap Motion performs poorly in these tasks when compared to a mouse or touchpad.
Keywords :
"Thumb","Performance evaluation","Mice","Computers","ISO Standards","Software"
Publisher :
ieee
Conference_Titel :
Pervasive and Embedded Computing and Communication Systems (PECCS), 2015 International Conference on
Type :
conf
Filename :
7483727