DocumentCode :
3777839
Title :
A new single-phase specific harmonic detection algorithm without phase-locked loop
Author :
Guo-Xian Shi; Xi-Ju Zong; Xin-Gong Cheng
Author_Institution :
Institute of Electric Power, School of Electronic Engineering, University of Jinan, 250022, China
fYear :
2015
Firstpage :
30
Lastpage :
33
Abstract :
In single-phase harmonic current detection algorithm of active power filter (APF), phase-locked loop (PLL) is always used to detect the frequency and phase of grid voltage. As a result, the harmonic detection result is directly affected by the performance of PLL. In order to solve this problem, combined with the demand for specific harmonic compensation, a new specific harmonic detection algorithm without PLL is proposed. Then the algorithm is analyzed theoretically. Finally, a simulink model of single-phase active power filter with the new algorithm is built. Simulation result proves the effectiveness of the new algorithm.
Keywords :
"Phase locked loops","Active filters","Power filters","Power harmonic filters","Load modeling","Detection algorithms","Algorithm design and analysis"