• DocumentCode
    3778118
  • Title

    Calibration of electronic current transformer with analog signal output

  • Author

    Zhou Liren; Pan Yang; Zhan Guozhong; Zhu Li; Mi Jianping; Lin Yan; Qin Yi

  • Author_Institution
    Shanghai Institute of Measurement and Testing Technology 201203, China
  • Volume
    2
  • fYear
    2015
  • fDate
    7/1/2015 12:00:00 AM
  • Firstpage
    846
  • Lastpage
    850
  • Abstract
    The performance of electronic transformer (ET) directly influences power measurement accuracy, of which output mode is quite different from that of electromagnetic transformers. Thus, conventional calibration method is not suitable for testing ET. This paper starts with the definition of ration error and phase error by IEC standard; analyzes problems in the existing calibration methods and then innovatively puts forward employing standard current transformer (CT), precise shunt and oscilloscope to measure ratio and phase error of ET with analog signal output at power frequency and high frequency (1kHz). Moreover, the data were compared and verified by two methods; the results were satisfied. Finally, the uncertainty was evaluated.
  • Keywords
    "Current measurement","Frequency measurement","Voltmeters","Uncertainty","Measurement uncertainty","Standards","Oscilloscopes"
  • Publisher
    ieee
  • Conference_Titel
    Electronic Measurement & Instruments (ICEMI), 2015 12th IEEE International Conference on
  • Type

    conf

  • DOI
    10.1109/ICEMI.2015.7494342
  • Filename
    7494342