• DocumentCode
    3779303
  • Title

    Transformer less, lower THD and highly efficient inverter system

  • Author

    Md. Khurshedul Islam;Md. Mizanur Rahman;Md. Fazle Rabbi

  • Author_Institution
    Department of Electrical & Electronic Engineering, International Islamic University Chittagong (IIUC), Bangladesh
  • fYear
    2015
  • Firstpage
    293
  • Lastpage
    296
  • Abstract
    Total Harmonic Distortion (THD) of a voltage or current signal causes power system losses, apparatus overheating and increases the power bills. This paper proposes the design and implementation of a transformer less single-phase inverter system that produces an output voltage of desired magnitude and frequency at a very lower THD. In `general inverter system´, a lower DC voltage is inverted into lower AC voltage which is further boost up to distribution level through a step up transformer. This system contains higher THD. But, the `proposed inverter system´ efficiently converts a 12V DC into 220V AC at a lower THD. By analysis on a real system, both topologies are simulated. Here PSIM simulation software is used. From the comparison of the simulation output, lower THD is demonstrated for `proposed inverter system´ than `general inverter system´.
  • Keywords
    "Inverters","Insulated gate bipolar transistors","Frequency control","Frequency conversion","Radio frequency","Inductors"
  • Publisher
    ieee
  • Conference_Titel
    Advances in Electrical Engineering (ICAEE), 2015 International Conference on
  • Type

    conf

  • DOI
    10.1109/ICAEE.2015.7506853
  • Filename
    7506853