Title :
Transformer less, lower THD and highly efficient inverter system
Author :
Md. Khurshedul Islam;Md. Mizanur Rahman;Md. Fazle Rabbi
Author_Institution :
Department of Electrical & Electronic Engineering, International Islamic University Chittagong (IIUC), Bangladesh
Abstract :
Total Harmonic Distortion (THD) of a voltage or current signal causes power system losses, apparatus overheating and increases the power bills. This paper proposes the design and implementation of a transformer less single-phase inverter system that produces an output voltage of desired magnitude and frequency at a very lower THD. In `general inverter system´, a lower DC voltage is inverted into lower AC voltage which is further boost up to distribution level through a step up transformer. This system contains higher THD. But, the `proposed inverter system´ efficiently converts a 12V DC into 220V AC at a lower THD. By analysis on a real system, both topologies are simulated. Here PSIM simulation software is used. From the comparison of the simulation output, lower THD is demonstrated for `proposed inverter system´ than `general inverter system´.
Keywords :
"Inverters","Insulated gate bipolar transistors","Frequency control","Frequency conversion","Radio frequency","Inductors"
Conference_Titel :
Advances in Electrical Engineering (ICAEE), 2015 International Conference on
DOI :
10.1109/ICAEE.2015.7506853