• DocumentCode
    3779685
  • Title

    Measurement of the temperature coefficient of capacitance

  • Author

    Isidore Bady

  • Author_Institution
    Squier Signal Laboratory, Port Monmouth, N.J.
  • fYear
    1949
  • Firstpage
    47
  • Lastpage
    48
  • Abstract
    Measurement of the temperature coefficient of capacitance involves the measurement of very small changes of relatively large capacitors. Hence a prime requisite for the measuring equipment is a high sensitivity. The “double heterodyne” method illustrated in the attached figure, has a very high sensitivity and can detect changes of 0,001 micromicrofarads in a 1000 micromicrofarad capacitor.
  • Keywords
    "Capacitors","Temperature measurement","Oscillators","Standards","Capacitance measurement","Capacitance","Temperature sensors"
  • Publisher
    ieee
  • Conference_Titel
    Electrical Insulation, 1949. annualReport 1949. Conference on
  • Print_ISBN
    978-1-5090-3126-9
  • Type

    conf

  • DOI
    10.1109/EIC.1949.7508710
  • Filename
    7508710