Abstract :
The RHIC coupling correction system has been commissioned during the Year 2000 run, which marked the successful first year of operation of the machine. The RHIC coupling correction system is described with particular emphasis on its flexibility, which allows using both global and local coupling compensation techniques. Coupling measurements and correction data are presented for the RHIC Blue and Yellow rings, together with the procedure used to reduce the minimum tune separation to 0.001, the typical resolution for tune measurements during run 2000. We further demonstrate how local coupling compensation in the interaction regions substantially reduces the strength of the skew quadrupole families used for global coupling compensation
Keywords :
accelerator magnets; beam handling equipment; electromagnets; ion accelerators; ion beams; storage rings; synchrotrons; Blue ring; RHIC; RUN 2000; Yellow ring; correction data; coupling correction system; global coupling compensation techniques; interaction regions; local coupling compensation techniques; minimum tune separation; skew quadrupoles; tune measurements; Analytical models; Calibration; Lattices; Linear particle accelerator; Logistics; Magnets; Packaging; Power supplies; Power system modeling; Resonance;