DocumentCode
3782116
Title
Generator winding design based on 25 year experience at Amos
Author
J. Oliver;R. Joho;B. Zimmerli;N. Krick;A. Huber
fYear
1999
Firstpage
305
Lastpage
307
Abstract
Over 25 years ago, American Electric Power (AEP) purchased for the John E. Amos Plant, Unit 3, the first of six new 1300 MW units. With a highly coordinated effort utilizing AEP´s experience and the manufacturer´s design and manufacturing capability, extraordinarily reliable generators were produced which have run for all these years with very little trouble. This paper shows the advantages to be achieved by careful consideration of all aspects of stator winding design in large powerful turbine generators: conductors, wedging, and end winding support. It is shown that when these issues are addressed correctly, 25 years and longer life is a reasonable expectation.
Keywords
"Stator windings","Manufacturing","Conductors","Copper","Cooling","Steel","Turbines","Solids","History","Insulation"
Publisher
ieee
Conference_Titel
Electric Machines and Drives, 1999. International Conference IEMD ´99
Print_ISBN
0-7803-5293-9
Type
conf
DOI
10.1109/IEMDC.1999.769098
Filename
769098
Link To Document