DocumentCode :
3782804
Title :
Diagnostics and aging of electrically conductive adhesives
Author :
P. Mach;M. Skvor;P. Szaraz
Author_Institution :
Dept. of Electrotechnol., Czech Tech. Univ., Prague, Czech Republic
Volume :
2
fYear :
2000
Firstpage :
517
Abstract :
Resistance and nonlinearity of the current vs. voltage characteristics (NAVC) of adhesive joints was investigated. The joints were prepared of four types of electrically conductive adhesives (ECA) on Cu clad FR4 laminate and on Cu clad FR4 laminate with gold coating on the Cu. The circuit layer was designed to make 4-point measurements possible. Adhesives were applied by dispensing. The boards were assembled by resistors of the value 0 /spl Omega/ recommended for assembly using adhesives. The samples were aged at the temperature of 200/spl deg/C and 160/spl deg/C, respectively, for different time. Significant changes of resistance and NAVC were found during aging of adhesives. It was found that NAVC is a parameter, which is very sensitive to changes of ECA and therefore could be very useful for diagnostics of these materials.
Keywords :
"Aging","Conductive adhesives","Laminates","Assembly","Electric resistance","Voltage","Gold","Coatings","Circuits","Conductivity measurement"
Publisher :
ieee
Conference_Titel :
Microelectronics, 2000. Proceedings. 2000 22nd International Conference on
Print_ISBN :
0-7803-5235-1
Type :
conf
DOI :
10.1109/ICMEL.2000.838744
Filename :
838744
Link To Document :
بازگشت