• DocumentCode
    3784414
  • Title

    3-D approach to designing the excitation coil of an electromagnetic flowmeter

  • Author

    A. Michalski;J. Starzynski;S. Wincenciak

  • Author_Institution
    Dept. of Electr. Eng., Warsaw Univ. of Technol., Poland
  • Volume
    51
  • Issue
    4
  • fYear
    2002
  • Firstpage
    833
  • Lastpage
    839
  • Abstract
    This paper presents a three-dimensional (3-D) hybrid numerical model of the electromagnetic flow meter. Compared to the two-dimensional (2-D) model used before, it is advantageous for the quality of computer simulation, but at the cost of computational burden. Our aim was to compare characteristics of the flowmeter obtained from 2-D and 3-D simulations to check if faster 2-D models can be used for computer-aided design of the device. The results of research show that the 3-D model must be used for optimal design of some parameters of the coil.
  • Keywords
    "Coils","Magnetic field measurement","Electrodes","Transducers","Shape","Numerical models","Two dimensional displays","Computer simulation","Computational efficiency","Fluid flow measurement"
  • Journal_Title
    IEEE Transactions on Instrumentation and Measurement
  • Publisher
    ieee
  • ISSN
    0018-9456
  • Type

    jour

  • DOI
    10.1109/TIM.2002.803502
  • Filename