• DocumentCode
    3784432
  • Title

    A monolithic signal processor for a neurophysiological telemetry system

  • Author

    M.G. Dorman;M.A. Prisbe;J.D. Meindl

  • Volume
    20
  • Issue
    6
  • fYear
    1985
  • Firstpage
    1185
  • Lastpage
    1193
  • Abstract
    A micropower signal-processor IC is the key component of an implantable telemetry system for neurophysiology. The bipolar/JFET/I/SUP 2/L chip uses digital and low-noise analog circuitry to amplify, filter, and multiplex eight channels of neutral, electrogram, and temperature data from unanesthetized and freely moving animals. Fully integrated continuous-time bandpass amplifiers incorporate a frequency-sensitive feedback network to prevent the amplification of input offset voltage. The system can telemeter data for over 500 h, permitting long-term neurophysiological investigations.
  • Keywords
    "Signal processing","Telemetry","Neurophysiology","JFET circuits","Band pass filters","Digital filters","Temperature","Animals","Frequency","Neurofeedback"
  • Journal_Title
    IEEE Journal of Solid-State Circuits
  • Publisher
    ieee
  • ISSN
    0018-9200
  • Type

    jour

  • DOI
    10.1109/JSSC.1985.1052457
  • Filename
    1052457