DocumentCode :
3784757
Title :
Eliminating short ending effects in the primary transducer of electromagnetic flow meters
Author :
A. Michalski;J. Starzynski;S. Wincenciak
Author_Institution :
Inst. of the Theor. of Electr. Eng. & Electr. Meas., Warsaw Tech. Univ., Poland
Volume :
39
Issue :
2
fYear :
2003
Firstpage :
1035
Lastpage :
1039
Abstract :
This paper describes a new method of primary transducer length optimization for electromagnetic flow meters. The method is based on eliminating a short ending effect that appears in the area where the magnetic field rapidly vanishes. The method uses numerical tools compatible with the cross section of the excitation coil design. It is based on a simple two-dimensional mathematical model of the primary transducer. The paper presents results of calculations for two water-to-ground conductivity ratios and for a rectangular flow channel.
Keywords :
"Transducers","Coils","Magnetic field measurement","Fluid flow measurement","Electromagnetic measurements","Electrodes","Electric variables measurement","Velocity measurement","Magnetic flux density","Electromagnetic fields"
Journal_Title :
IEEE Transactions on Magnetics
Publisher :
ieee
ISSN :
0018-9464
Type :
jour
DOI :
10.1109/TMAG.2003.808581
Filename :
1190065
Link To Document :
بازگشت