• DocumentCode
    3792651
  • Title

    An optically isolated hybrid two-stage current transformer for measurements at high voltage

  • Author

    B. Djokic;E. So

  • Author_Institution
    Inst. for Nat. Meas. Stand., Nat. Res. Council of Canada, Ottawa, Ont., Canada
  • Volume
    55
  • Issue
    4
  • fYear
    2006
  • Firstpage
    1204
  • Lastpage
    1207
  • Abstract
    The development of a high-voltage (HV) current measurement system for on-site/in-situ calibrations in power systems is described in the paper. The system is based on an optically isolated hybrid two-stage current transformer with electronic circuitry that performs A/D conversion. It uses a fiber optic link for data transmission to a ground station and a laser-driven fiber optic link for supplying power to the electronic circuitry of the remote module at HV. The uncertainty of the current-ratio measurement is estimated to be less than 100middot10-6 both in-phase and quadrature
  • Keywords
    "Current transformers","Current measurement","Voltage measurement","Hybrid power systems","Circuits","Optical fibers","Calibration","Power system measurements","Data communication","Satellite ground stations"
  • Journal_Title
    IEEE Transactions on Instrumentation and Measurement
  • Publisher
    ieee
  • ISSN
    0018-9456
  • Type

    jour

  • DOI
    10.1109/TIM.2006.876526
  • Filename
    1658372