• DocumentCode
    3795695
  • Title

    A new method for measurement of safety rod drop times

  • Author

    M. Pesic;P. Marinkovic;D. Stefanovic

  • Author_Institution
    Nucl. Eng. Lab., Inst. of Nucl. Sci. VINCA, Beograd, Yugoslavia
  • Volume
    39
  • Issue
    5
  • fYear
    1992
  • Firstpage
    1502
  • Lastpage
    1505
  • Abstract
    A method for measurement of safety rod drop times is proposed that is based on a fast electromagnetic transducer and an analog-to-digital converter (ADC) connected to a computer system. Evaluation of recorded data is conducted by computer codes that were developed. The first measurements performed at the fast-thermal core HERBE constructed in the RB heavy water nuclear reactor at the Nuclear Engineering Laboratory of the Vinca Institute showed that a relative uncertainty of less than 6% can be achieved in determination of the rod drop time with time intervals ranging from 0.4 to 10.0 s.
  • Keywords
    "Transducers","Time measurement","Strontium","Analog-digital conversion","Performance evaluation","Inductors","Laboratories","Switches","Electrical safety","Voltage"