DocumentCode :
3796076
Title :
Effective control of the error in a direct measurement of core-loss power
Author :
F.D. Tan;J.L. Vollin;S.M. Cuk
Author_Institution :
Power Electron. Group, California Inst. of Technol., Pasadena, CA, USA
Volume :
31
Issue :
3
fYear :
1995
Firstpage :
2280
Lastpage :
2284
Abstract :
Accuracy of a direct measurement of core-loss power is severely limited in many applications by the extra phase shift between the measured voltage and current. An analysis of the error is for the first time performed, which not only unfolds the hidden physical nature behind it, but also reveals a simple and effective method to control the sensitivity and hence the error. This method can also be used to satisfy a prescribed tolerance. Extensive measurements on a TDK PC40 core yield results which support the analysis.
Keywords :
"Error correction","Power measurement","Phase measurement","Current measurement","Error analysis","Magnetic field measurement","Magnetic cores","Power electronics","Voltage","Core loss"
Journal_Title :
IEEE Transactions on Magnetics
Publisher :
ieee
ISSN :
0018-9464
Type :
jour
DOI :
10.1109/20.376232
Filename :
376232
Link To Document :