• DocumentCode
    3798491
  • Title

    Thermal Parametric Imaging in the Evaluation of Skin Burn Depth

  • Author

    Jacek Ruminski;Mariusz Kaczmarek;Alicja Renkielska;Antoni Nowakowski

  • Author_Institution
    Dept. of Biomed. Eng., Gdansk Univ. of Technol.
  • Volume
    54
  • Issue
    2
  • fYear
    2007
  • Firstpage
    303
  • Lastpage
    312
  • Abstract
    The aim of this paper is to determine the extent to which infrared (IR) thermal imaging may be used for skin burn depth evaluation. The analysis can be made on the basis of the development of a thermal model of the burned skin. Different methods such as the traditional clinical visual approach and the IR imaging modalities of static IR thermal imaging, active IR thermal imaging and active-dynamic IR thermal imaging (ADT) are analyzed from the point of view of skin burn depth diagnostics. In ADT, a new approach is proposed on the basis of parametric image synthesis. Calculation software is implemented for single-node and distributed systems. The properties of all the methods are verified in experiments using phantoms and subsequently in vivo with animals with a reference histopathological examination. The results indicate that it is possible to distinguish objectively and quantitatively burns which will heal spontaneously within three weeks of infliction and which should be treated conservatively from those which need surgery because they will not heal within this period
  • Keywords
    "Skin","Optical imaging","Magnetic resonance imaging","Surgery","Infrared detectors","Ultrasonic imaging","Wounds","Infrared imaging","Image analysis","Biomedical measurements"
  • Journal_Title
    IEEE Transactions on Biomedical Engineering
  • Publisher
    ieee
  • ISSN
    0018-9294
  • Type

    jour

  • DOI
    10.1109/TBME.2006.886607
  • Filename
    4067165