DocumentCode :
3806861
Title :
Digital Metering of Power Components According to IEEE Standard 1459-2000 Using the Newton-Type Algorithm
Author :
Vladimir V. Terzija;Vladimir Stanojevic;Marjan Popov;Lou van der Sluis
Author_Institution :
Manchester Univ., Manchester
Volume :
56
Issue :
6
fYear :
2007
Firstpage :
2717
Lastpage :
2724
Abstract :
In this paper, a new two-stage Newton-type algorithm for the measurement of power components according to the IEEE Standard 1459-2000 is presented. To estimate their spectra and fundamental frequency, in the first stage, the current and voltage signals are processed, whereas in the second stage, the power components are calculated based on the results obtained in the first stage. The algorithm considers the frequency as an unknown parameter and simultaneously estimates it with the input signal spectrum. Through this, the algorithm becomes insensitive to frequency changes and the problem becomes non-linear. The algorithm performance is tested using computer-simulated and laboratory tests.
Keywords :
"Power system harmonics","Frequency estimation","Voltage","Measurement standards","Jacobian matrices","Power measurement","Signal processing","Parameter estimation","Phase noise","Testing"
Journal_Title :
IEEE Transactions on Instrumentation and Measurement
Publisher :
ieee
ISSN :
0018-9456
Type :
jour
DOI :
10.1109/TIM.2007.908235
Filename :
4389146
Link To Document :
بازگشت