Discussion on Role of metal debris in the performance of stop joints as used in 275 kV and 400 kV self-contained oil-filled cable circuits and Partial discharges in power-cable joints: their propagation along a crossbonded circuit and methods for their de
Volume :
129
Issue :
2
fYear :
1982
fDate :
3/1/1982 12:00:00 AM
Firstpage :
93
Lastpage :
100
Abstract :
The authors are to be congratulated on presenting two papers on a very difficult subject. Paper 1009C has honestly given the results of extensive experimental work, including the inconsistencies in Table 1. There is no doubt that this is a complex subject, blending as it does the disciplines of engineering, physics and chemistry with a multitude of variables. A simple explanation often is not enough, and I believe the suggestions given in paper 1009C are possibly insufficient to explain the behaviour in service or the results of some of our own experiments