DocumentCode :
383083
Title :
Scattering lights and inclination of filamentary particle in electrostatic sorting system
Author :
Yatsuzuka, Kyoko ; Inaba, Takaaki ; Asano, Kazutoshi
Author_Institution :
Yamagata Univ., Japan
Volume :
3
fYear :
2002
fDate :
13-18 Oct. 2002
Firstpage :
1829
Abstract :
We have investigated an electrostatic sorting system based on the mechanism of a cell sorter system. Particles dispersed in liquid are carried by the flow and ejected from a nozzle one by one, being kept inside the liquid column. A laser beam illuminates the liquid column just below the nozzle. When a particle is passing by there, the scattering light is produced and detected by two photomultipliers (PMTs). A computer analyzes the scattered light intensities and classifies the particle by size or its shape. The particle is flowing down to the breaking point of the liquid column, where an electrode is put close to the liquid column end. When the particle reaches this point, a pulsed voltage is applied to the electrode to make a charged droplet with the particle. This charged droplet with the particle is deflected in the uniform electric field and collected separately. As for the spherical particles it has been confirmed the particles of 5-33 /spl mu/m diameter can be sorted by size with up to 90% efficiency. For filamentary particles, it has been revealed experimentally that the scattered lights detected by two PMTs are not generated at the same time. It suggests that the time difference between two scattered light pulses is related to the particle length. In this report the particles inside the liquid column are observed by means of a video microscopic system and a single flash light, those results are combined with the scattered light patterns. The relation between the particle length and the the time difference of two scattered lights has been confirmed. The change of the inclination of a filamentary particle during flowing down the liquid column is also observed. The deformation of the liquid column due to the particle has been examined to improve the sorting efficiency.
Keywords :
drops; electrodes; electrostatic devices; light scattering; nozzles; particle separators; photomultipliers; separation; 5 to 33 micron; 90 percent; breaking point; cell sorter system; charged droplet; electrode; electrostatic sorting system; filamentary particle inclination; flash light; laser beam; liquid column; liquid column end; nozzle; photomultipliers; pulsed voltage; scattered light pulses; scattering lights; sorting efficiency improvement; spherical particles; uniform electric field; video microscopic system; Electrodes; Electrostatics; Laser beams; Light scattering; Microscopy; Particle scattering; Photomultipliers; Shape; Sorting; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Industry Applications Conference, 2002. 37th IAS Annual Meeting. Conference Record of the
Conference_Location :
Pittsburgh, PA, USA
ISSN :
0197-2618
Print_ISBN :
0-7803-7420-7
Type :
conf
DOI :
10.1109/IAS.2002.1043781
Filename :
1043781
Link To Document :
بازگشت