PD frequency characteristics for a void bounded with LDPE
Author :
Kim, C.-S. ; Hirase, T. ; Mizutani, T.
Author_Institution :
Nagoya Univ., Japan
fYear :
2002
fDate :
2002
Firstpage :
712
Lastpage :
715
Abstract :
The change in PD (partial discharge) pulse shape for a void bounded with LDPE was measured using a time-resolved measurement system with an ultra-wideband detector. Phase-resolved patterns also were obtained by a conventional PD measuring system. The frequency spectrum analysis of PD pulse waveform showed that ageing stages have unique frequency distributions. PD patterns also have different frequency ranges. The frequency distribution was concluded to be applicable to the insulation diagnosis.
Keywords :
ageing; insulation testing; partial discharge measurement; polyethylene insulation; voids (solid); LDPE insulation diagnosis; ageing process; frequency distribution; partial discharge pulse shape; phase-resolved pattern; time-resolved measurement system; ultra-wideband detector; void defect; Aging; Detectors; Frequency; Partial discharge measurement; Partial discharges; Phase measurement; Pulse measurements; Pulse shaping methods; Shape measurement; Ultra wideband technology;