• DocumentCode
    3848240
  • Title

    Determination of formative time of electrical breakdown in nitrogen-filled tube

  • Author

    M.M. Pejovic;V.L. Markovic;G.S. Ristic;S. Mekic

  • Author_Institution
    Fac. of Electron. Eng., Nis Univ., Serbia
  • Volume
    143
  • Issue
    6
  • fYear
    1996
  • Firstpage
    413
  • Lastpage
    415
  • Abstract
    The formative time in a nitrogen-filled tube at pressure of 1.3 mbar was determined using Laue distributions and histograms of the time delay of electrical breakdown. It was shown that using these methods the formative time can be determined when it is of the same order of magnitude as the statistical time delay. The obtained values are in good agreement with the values which were measured by memory oscilloscope.
  • Keywords
    Electric breakdown
  • Journal_Title
    IEE Proceedings - Science, Measurement and Technology
  • Publisher
    iet
  • ISSN
    1350-2344
  • Type

    jour

  • DOI
    10.1049/ip-smt:19960650
  • Filename
    553244