    Low frequency current density imaging (LFCDI) using a magnetic resonance (MR) imager has been shown to accurately measure electrical current density inside a phantom. CDI measures the magnetic field generated by the current and converts it to current density (CD) by computing its curl. Therefore, CDI avoids both the inverse problem and invasiveness of other electrical measurement techniques such as electrical impedance tomography and direct electrode measurement. This makes CDI an ideal technique for studying the current flow inside the body during electrical therapies such as defibrillation where the current density in tissue is closely associated with the efficacy. Here we report simultaneous measurements of current density at all points within the pig torso during an electrical current application through defibrillation electrodes. Current flow was visualized by computing streamlines from the current density vectors. We observed current flow over the chest walls in agreement with the current literature. However, complex and unexpected current flow patterns were seen inside the heart as well as in the surrounding vasculature. This study represents the first noninvasive volume current measurement inside the pig torso during an electrical current application.
  • Keywords
    bioelectric phenomena; biological tissues; biomedical MRI; biomedical electrodes; biomedical imaging; current density; defibrillators; electric current measurement; magnetic field measurement; body; chest walls; curl; current density vectors; current flow; defibrillation electrodes; electrical current density; electrical current pathways; electrical therapies; low frequency current density imaging; magnetic field; magnetic resonance imager; noninvasive volume current measurement; phantom; pig torso; streamlines; surrounding vasculature; Current density; Current measurement; Defibrillation; Density measurement; Electric variables measurement; Electrodes; Frequency; Magnetic field measurement; Magnetic resonance imaging; Torso;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology, 2002. 24th Annual Conference and the Annual Fall Meeting of the Biomedical Engineering Society EMBS/BMES Conference, 2002. Proceedings of the Second Joint
  • ISSN
    1094-687X
  • Print_ISBN
    0-7803-7612-9
  • Type

    conf

  • DOI
    10.1109/IEMBS.2002.1106205
  • Filename
    1106205