• DocumentCode
    385336
  • Title

    Assessment of object-based video compression for epilepsy monitoring

  • Author

    Sun, Mingui ; Liu, Qiang ; Scheuer, Mark L. ; Sclabassi, Robert J.

  • Author_Institution
    Lab. for Computational Neurosci., Pittsburgh Univ., PA, USA
  • Volume
    2
  • fYear
    2002
  • fDate
    2002
  • Firstpage
    1045
  • Abstract
    Simultaneous recording of the electroencephalogram (EEG) and video is often conducted during the evaluation of patients with seizures. This recording often lasts for several days, resulting in a tremendous amount of data. We have investigated an object based video compression method specifically tailored to epilepsy monitoring. Our data indicate that this method out-performs the conventional video compression method by a wide margin.
  • Keywords
    biomedical optical imaging; data compression; diseases; electroencephalography; patient monitoring; video coding; electroencephalogram; epilepsy monitoring; object-based video compression; patient evaluation; seizures; simultaneous recording; Computer displays; Data compression; Electroencephalography; Epilepsy; MPEG 4 Standard; Patient monitoring; Sun; Transform coding; Video compression; Video recording;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology, 2002. 24th Annual Conference and the Annual Fall Meeting of the Biomedical Engineering Society EMBS/BMES Conference, 2002. Proceedings of the Second Joint
  • ISSN
    1094-687X
  • Print_ISBN
    0-7803-7612-9
  • Type

    conf

  • DOI
    10.1109/IEMBS.2002.1106268
  • Filename
    1106268