• DocumentCode
    3853956
  • Title

    Active motor terminal overvoltage mitigation method for parallel voltage source inverters

  • Author

    J. Korhonen;T. Itkonen;J.-P. Strom;J. Tyster;P.T. Silventoinen

  • Author_Institution
    Department of Electrical Engineering, Institute of Energy Technology, Lappeenranta University of Technology, P.O. Box 20, FI-53851 Lappeenranta, Finland
  • Volume
    5
  • Issue
    8
  • fYear
    2012
  • fDate
    9/1/2012 12:00:00 AM
  • Firstpage
    1430
  • Lastpage
    1437
  • Abstract
    Electrical motor fed by voltage source inverters has been known to face transient overvoltage problems caused by the inverter switching operations. With the parallel inverter topology and with the modulation strategy presented in this study, the motor terminal overvoltage can be reduced without any passive filtering. The parallel inverter topology has individual motor leads from each inverter connected at the motor terminals. Modulation strategy for any number of parallel inverters with current balancing is presented. Experimental results are presented for two and three parallel standard industry frequency converters to verify the method.
  • Journal_Title
    IET Power Electronics
  • Publisher
    iet
  • ISSN
    1755-4535
  • Type

    jour

  • DOI
    10.1049/iet-pel.2011.0232
  • Filename
    6340678