DocumentCode :
3861498
Title :
An analysis of three-phase low-harmonic rectifiers applying the third-harmonic current injection
Author :
P. Pejovic;Z. Janda
Author_Institution :
Fac. of Electr. Eng., Belgrade Univ., Serbia
Volume :
14
Issue :
3
fYear :
1999
Firstpage :
397
Lastpage :
407
Abstract :
An analysis of the three-phase low-harmonic rectifiers applying passive third-harmonic current injection networks is presented in this paper. Optimal amplitude of the injected current to minimize the input current total-harmonic distortion (THD) is derived as a function of the injected current phase displacement. Power aspects of the third-harmonic current injection are analyzed, and it is shown that improvement in the input current THD could be obtained at the expense of the power taken by the current injection network. In the case of optimal current injection, the power taken by the current injection network is shown to be equal to 8.571% of the input power, resulting in the input current THD of 5.125%. Effects of unwanted higher order harmonics in the injected currents are studied for two previously proposed passive current injection networks. The current injection networks are compared under the constraint that volt-ampere ratings of applied components are the same. Analytically obtained results are experimentally verified.
Keywords :
"Rectifiers","Diodes","Bridge circuits","Power system harmonics","Harmonic distortion","Power conversion harmonics","Power electronics","Voltage","Phase distortion","Power quality"
Journal_Title :
IEEE Transactions on Power Electronics
Publisher :
ieee
ISSN :
0885-8993
Type :
jour
DOI :
10.1109/63.761682
Filename :
761682
Link To Document :
بازگشت