DocumentCode :
3861516
Title :
Average-current-mode control of two-input buck postregulators used in power-factor correctors
Author :
J. Sebastian;P.J. Villegas;M. Hernando;F. Nuno;F. Fernandez-Linera
Author_Institution :
Dept. de Ingenieria Electrica, Electron. de Comput. y Sistemas, Oviedo Univ., Spain
Volume :
46
Issue :
3
fYear :
1999
Firstpage :
569
Lastpage :
576
Abstract :
The use of the average-current-mode control in the two-input buck postregulator is studied in this paper. Using this type of control, the attenuation of the input voltage ripple (100-120 Hz) increases in relation to the one obtained when a conventional voltage-mode control (with or without feedforward) is used and, therefore, lower bulk capacitors can be used to obtain a very low voltage ripple at the output, which is very important when a battery is connected at the output. This is very common in distributed power supply systems.
Keywords :
"Voltage control","Capacitors","Low voltage","Pulse width modulation","Batteries","Power supplies","Bandwidth","Feedback loop","Filters","Switching frequency"