Title : 
Transmission and reflection SPR disposable fibre probes for bio-chemical sensing
         
        
            Author : 
Papiya Dhara;Massimo Olivero;Alberto Vallan;Guido Perrone;V. K. Singh
         
        
            Author_Institution : 
Dept. of Electronics and Telecommunications, Politecnico di Torino, Torino, Italy
         
        
        
            fDate : 
5/15/2016 12:00:00 AM
         
        
        
        
            Abstract : 
A comparison between the characteristics of transmission and of reflection based surface plasmon resonance (SPR) fiber sensors is presented. Both sensors are built using a multimode fiber with 400 μm silica core diameter, un-cladded on a length of 2 cm and then coated with a 50 nm gold layer. The reflection based setup uses a bifurcated fiber bundle to avoid complex and expensive circulators or couplers. The effect of misalignments and mating tolerances are investigated. The comparison between transmission and reflection based setups shows that the same fiber sensor exhibits a higher sensitivity when used in the reflection based configuration. The latter is also advantageous since it allows the use of the fiber sensor as a disposable probe.
         
        
            Keywords : 
"Optical fiber sensors","Reflection","Refractive index","Plasmons","Optical fiber couplers"
         
        
        
            Conference_Titel : 
BioPhotonics (BioPhotonics), 2015 International Conference on
         
        
        
            DOI : 
10.1109/BioPhotonics.2015.7304041