• DocumentCode
    3863339
  • Title

    Studies on corona in transformer oil by measurement of space charge

  • Author

    M. Hayashi;O. Yamamoto;H. Isa;C. Uenosono;Y. Mino;T. Tani

  • Author_Institution
    Department of Electrical Engineering, Kyoto University, Yoshida-honmachi Sakyo-ku, (Japan)
  • fYear
    1984
  • fDate
    7/1/1984 12:00:00 AM
  • Firstpage
    204
  • Lastpage
    208
  • Abstract
    Studies were carried out for needle-plane gaps with a comparatively long separation in transformer oil. Relations between needle voltages and space charge quantities due to coronas by lightning impulse and AC voltages were obtained. It was found that the charge quantities for AC voltages were larger by 1.2 times and 6 times than that for the positive and the negative impulse voltages respectively. It was also found that the space charges by impulse voltages were reduced considerably by back-discharge phenomena.
  • Keywords
    "Corona","Space charge","Needles","Probes","Discharges (electric)","Electrodes","Oil insulation"