DocumentCode
388078
Title
An image reconstruction from limited view angle projection data
Author
Saito, Tsuneo ; Kudo, Hiroyuki
Author_Institution
Tohuko University, Sendai, Japan
Volume
12
fYear
1987
fDate
31868
Firstpage
1187
Lastpage
1190
Abstract
In this paper, we deal with the problem on tomographic image reconstruction from limited view angle projection data. Based on the Helgason-Ludwig consistency condition, a new procedure for completion of incomplete projection data is introduced to improve the reconstructed image quality. Using regularization method the robust algorithm to the presence of noise is presented. The performance of new algorithm was confirmed in the numerical simulation. The reconstructed images were quantitatively improved by this procedure with realistic amount of computation.
Keywords
Computed tomography; Data engineering; Extrapolation; Frequency; Image quality; Image reconstruction; Image storage; Noise robustness; Polynomials; Sampling methods;
fLanguage
English
Publisher
ieee
Conference_Titel
Acoustics, Speech, and Signal Processing, IEEE International Conference on ICASSP '87.
Type
conf
DOI
10.1109/ICASSP.1987.1169761