• DocumentCode
    389970
  • Title

    Dead-zone digital controller for improved dynamic response of power factor preregulators

  • Author

    Prodic, Aleksandar ; Maksimovic, Dragan ; Erickson, Robert W.

  • Author_Institution
    Dept. of Electr. & Comput. Eng., Colorado Univ., Boulder, CO, USA
  • Volume
    1
  • fYear
    2003
  • fDate
    9-13 Feb. 2003
  • Firstpage
    382
  • Abstract
    This paper presents a simple control method for improvement of dynamic responses in a digitally controlled low-harmonic rectifier with power factor correction (PFC). The controller uses a fixed or self-adjusting dead zone in analog-to-digital conversion to eliminate the output capacitor ripple from the voltage control loop. The proposed control methods are tested in a completely digitally controlled 200 W boost PFC operating at 200 kHz switching frequency. Experimental results show that the simple controller implementation results in low current harmonics and significantly improved output voltage transient responses.
  • Keywords
    analogue-digital conversion; digital control; power conversion harmonics; power factor correction; rectifying circuits; switching convertors; transient response; voltage control; 200 W; 200 kHz; analog-to-digital conversion; dead-zone digital controller; low-harmonic rectifier; output capacitor ripple elimination; output voltage transient responses improvement; power factor correction; self-adjusting dead zone; switching frequency; voltage control loop; Analog-digital conversion; DC-DC power converters; Digital control; Frequency; Power electronics; Reactive power; Rectifiers; Regulators; Switching converters; Voltage control;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Applied Power Electronics Conference and Exposition, 2003. APEC '03. Eighteenth Annual IEEE
  • Conference_Location
    Miami Beach, FL, USA
  • Print_ISBN
    0-7803-7768-0
  • Type

    conf

  • DOI
    10.1109/APEC.2003.1179242
  • Filename
    1179242