DocumentCode :
392528
Title :
ESD effect of deshunting sequences to recording heads using human body model
Author :
Siritaratiwat, A. ; Jutong, N. ; Pinnoi, J. ; Puprichitkul, C. ; Suwannata, N.
Volume :
1
fYear :
2002
fDate :
2002
Firstpage :
39
Abstract :
The electrostatic discharge (ESD) effect in recording heads in the process of deshunting is studied using human body model (HBM). The sequence of deshunting is thought to cause the damage of a gap between the GMR head sensor and the bottom shield. It is found from the simulation, based on real values, that a typical deshunting sequence as W- to R- can destroy the gap unless a completed protection is used. In a case of all four leads are deshunted, the less damage can be observed.
Keywords :
electrostatic discharge; magnetic heads; magnetic recording; deshunting; electrostatic discharge; electrostatic discharge effect; human body model; recording head; Biological system modeling; CD recording; Circuits; Disk recording; Electrostatic discharge; Humans; Immune system; Magnetic heads; Protection; Switches;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Industrial Technology, 2002. IEEE ICIT '02. 2002 IEEE International Conference on
Print_ISBN :
0-7803-7657-9
Type :
conf
DOI :
10.1109/ICIT.2002.1189858
Filename :
1189858
Link To Document :