Experimental evaluation of some possible nonlinearity indicators
Author :
Bigelow, Timothy A. ; O´Brien, William D., Jr.
Author_Institution :
Dept. of Electr. & Comput. Eng., Illinois Univ., Urbana, IL, USA
Volume :
2
fYear :
2002
fDate :
8-11 Oct. 2002
Firstpage :
1391
Abstract :
Due to regulatory reasons, the output levels of ultrasound sources for use in medical applications must be known. Currently, this is done by making focal pressure measurements for a very large number of drive voltage amplitudes and then linearly derating the measured pressure levels. In order to reduce calibration times, some have proposed to linearly extrapolate pressures rather than perform direct measurements. However, nonlinear propagation effects corrupt the linear extrapolation and derating procedure. Thus, a reliable indicator of nonlinearity is needed to identify when linear extrapolation/derating would be valid. In this study, eight different nonlinearity indicators were evaluated experimentally in terms of their correspondence to the linear extrapolation error. Spherically focused ultrasound transducers were selected and excited to test the indicators sensitivity to frequency (3 - 8 MHz), f/# (1 and 2), transducer diameter (1.905 and 5.08 cm), pulse duration (1 and 3 cycles), and pulse phase (0° and 180°). None of the eight nonlinearity indicators yielded consistent results. The lack of consistency resulted from the competing effects of nonlinear absorption and asymmetric distortion, which have yet to be combined into a unified theory.
Keywords :
biomedical ultrasonics; calibration; extrapolation; ultrasonic transducers; 1.905 cm; 3 to 8 MHz; 5.08 cm; asymmetric distortion; calibration times; derating procedure; drive voltage amplitudes; focal pressure measurements; frequency; linear extrapolation error; linear extrapolation/derating; medical applications; nonlinear absorption; nonlinear propagation effects; nonlinearity indicators; output levels; pressure levels; pulse duration; pulse phase; regulatory reasons; spherically focused ultrasound transducers; transducer diameter; ultrasound sources; Biomedical equipment; Calibration; Current measurement; Extrapolation; Medical services; Pressure measurement; Ultrasonic imaging; Ultrasonic transducers; Ultrasonic variables measurement; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Ultrasonics Symposium, 2002. Proceedings. 2002 IEEE
ISSN :
1051-0117
Print_ISBN :
0-7803-7582-3
Type :
conf
DOI :
10.1109/ULTSYM.2002.1192555
Filename :
1192555
Link To Document :
بازگشت