• DocumentCode
    393521
  • Title

    NiC eutectic point

  • Author

    Imai, Motoya

  • Author_Institution
    Tamagawa Univ., Tokyo, Japan
  • Volume
    2
  • fYear
    2002
  • fDate
    5-7 Aug. 2002
  • Firstpage
    1043
  • Abstract
    NiC eutectic point (approximately 1329°C) is studied as a fixed point for the calibration of Pt/Pd thermocouples that have useful measuring temperature up to 1500°C. It is found that reproducibility in the temperature of Melting Plateau is 0.1°C and that that of Freezing Plateau is 0.1°C.
  • Keywords
    calibration; thermocouples; calibration; eutectic point; fixed point; thermocouple; Bridges; Calibration; Copper; Furnaces; Nickel; Reproducibility of results; Solids; Temperature distribution; Temperature measurement; Wire;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    SICE 2002. Proceedings of the 41st SICE Annual Conference
  • Print_ISBN
    0-7803-7631-5
  • Type

    conf

  • DOI
    10.1109/SICE.2002.1195317
  • Filename