• DocumentCode
    393625
  • Title

    3D flow tomography with electromagnetic flowmeter

  • Author

    Katoh, Takayuki ; Honda, Satoshi

  • Author_Institution
    Fac. of Sci. & Technol., Keio Univ., Kanagawa, Japan
  • Volume
    1
  • fYear
    2002
  • fDate
    5-7 Aug. 2002
  • Firstpage
    535
  • Abstract
    Magnetic flowmeters, which have been one of the standard instrument to measure liquid flowrate in industry, are applied to tomographic imaging of flow velocity field. It is possible to evaluate velocity profiles through the proper design of the magnetic field. In this paper, we propose a new design of the 3D field excitation with two sets of eight magnetic poles and of eight signal pick-up electrodes. From the simulation study under a laminar swirling flow, that the reconstruction of 3D velocity distribution can be achieved.
  • Keywords
    electromagnetic devices; flowmeters; laminar flow; swirling flow; tomography; 3D field excitation; 3D flow tomography; 3D velocity distribution reconstruction; electromagnetic flowmeter; flow velocity field; laminar swirling flow; liquid flowrate; magnetic flowmeters; magnetic poles; signal pick-up electrodes; tomographic imaging; velocity profiles; Electrodes; Electromagnetic measurements; Fluid flow measurement; Instruments; Magnetic field measurement; Magnetic liquids; Measurement standards; Signal design; Tomography; Velocity measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    SICE 2002. Proceedings of the 41st SICE Annual Conference
  • Print_ISBN
    0-7803-7631-5
  • Type

    conf

  • DOI
    10.1109/SICE.2002.1195462
  • Filename
    1195462