DocumentCode
396341
Title
A new method for evaluating harmonic distortion in push-pull output stages
Author
Giustolisi, G. ; Palumbo, G.
Author_Institution
Catania Univ., Italy
Volume
1
fYear
2003
fDate
25-28 May 2003
Abstract
In this paper, a new method for analytically evaluating the harmonic distortion in push-pull stages by circuit inspection is introduced. It is based on modeling each push-pull device in the stage with different third order polynomials. The coefficients of these polynomials may be evaluated by straightforward measurements or by pencil-and-paper analysis of the real transcharacteristic of the stage. The resulting theory was validated by simulations and is able to predict the harmonic distortion behavior of a push-pull output stage over a wide range of input values.
Keywords
differential amplifiers; harmonic distortion; polynomials; circuit inspection; harmonic distortion; push-pull output stage; third-order polynomial model; transcharacteristic; Circuit simulation; Distortion measurement; Energy measurement; Harmonic analysis; Harmonic distortion; High definition video; Inspection; Polynomials; Predictive models; Total harmonic distortion;
fLanguage
English
Publisher
ieee
Conference_Titel
Circuits and Systems, 2003. ISCAS '03. Proceedings of the 2003 International Symposium on
Print_ISBN
0-7803-7761-3
Type
conf
DOI
10.1109/ISCAS.2003.1205543
Filename
1205543
Link To Document