• DocumentCode
    39885
  • Title

    Toward Volumetric MR Thermometry With the MASTER Sequence

  • Author

    Marx, Michael ; Plata, Juan ; Pauly, Kim Butts

  • Author_Institution
    Radiol. Dept., Stanford Univ., Stanford, CA, USA
  • Volume
    34
  • Issue
    1
  • fYear
    2015
  • fDate
    Jan. 2015
  • Firstpage
    148
  • Lastpage
    155
  • Abstract
    MR temperature monitoring is an indispensable tool for high intensity focused ultrasound. In this paper, a new technique known as MASTER (multiple adjacent slice thermometry with excitation refocusing) is presented which improves the speed and accuracy of multiple-slice MR thermometry. Defocusing the magnetization after exciting a slice allows for multiple slices to be excited concurrently and stored in k-space. The magnetization from each excitation is then refocused and read in sequence. This approach increases TE for each slice, greatly improving temperature SNR as compared to conventional slice interleaving. Gradient sequence design optimization is required to minimize diffusion losses while maintaining high sequence efficiency. Flexibility in selecting position, update rate, accuracy, and voxel size for each slice independently allows for freedom in design to fit different application needs. Results are shown in phantom and in vivo validating the feasibility of the sequence, and comparing it to interleaved GRE. Sample design curves are presented that contrast the MASTER design space with that of interleaved GRE thermometry.
  • Keywords
    biodiffusion; biomedical MRI; brain; image sequences; magnetisation; medical image processing; optimisation; patient monitoring; phantoms; temperature measurement; MASTER design space; MASTER sequence; MR temperature monitoring; conventional slice interleaving; diffusion losses minimisation; gradient sequence design optimization; high intensity focused ultrasound. In; high sequence efficiency; interleaved GRE thermometry; k-space; magnetization defocusing; multiple adjacent slice thermometry-with-excitation refocusing; multiple-slice MR thermometry; phantom; sample design curves; update rate; volumetric MR thermometry; Accuracy; Heating; In vivo; Monitoring; Signal to noise ratio; Temperature measurement; Uncertainty; Brain; magnetic resonance imaging (MRI); temperature measurement;
  • fLanguage
    English
  • Journal_Title
    Medical Imaging, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0278-0062
  • Type

    jour

  • DOI
    10.1109/TMI.2014.2349912
  • Filename
    6881715