  • Abstract
    The process performance for ULVAC´s IW-630 200/300 mm medium current ion implanter is reviewed. The IW-630 was designed to ensure high beam parallelism, high-energy purity, and low defect contamination through the use of a ground magnet. The analyses presented include beam parallelism, energy purity, particle contamination, metals contamination, dose uniformity and repeatability.
  • Keywords
    focused ion beam technology; ion implantation; particle beam diagnostics; semiconductor doping; 200 mm; 300 mm; ULVAC IW-630 200/300mm implanter; beam parallelism; dose uniformity; energy purity; ground magnet; high beam parallelism; high-energy purity; low defect contamination; medium current ion implanter; metals contamination; particle contamination; process performance; repeatability; Acceleration; Contamination; Implants; Ion sources; Magnetic analysis; Magnetic separation; Optical filters; Optical pumping; Particle beam optics; Particle beams;